听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览JOURNAL OF BIOMEDICAL OPTICS期刊下所有文献
  • Needle-based fluorescence endomicroscopy via structured illumination with a plastic, achromatic objective.

    abstract::In order to diagnose cancer, a sample must be removed, prepared, and examined under a microscope, which is expensive, invasive, and time consuming. Fiber optic fluorescence endomicroscopy, where an image guide is used to obtain high-resolution images of tissue in vivo, has shown promise as an alternative to convention...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.096003

    authors: Kyrish M,Dobbs J,Jain S,Wang X,Yu D,Richards-Kortum R,Tkaczyk TS

    更新日期:2013-09-01 00:00:00

  • Tumor-associated macrophages and stromal TNF-α regulate collagen structure in a breast tumor model as visualized by second harmonic generation.

    abstract::Collagen fibers can be imaged with second harmonic generation (SHG) and are associated with efficient tumor cell locomotion. Preferential locomotion along these fibers correlates with a more aggressively metastatic phenotype, and changes in SHG emission properties accompany changes in metastatic outcome. We therefore ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086003

    authors: Burke RM,Madden KS,Perry SW,Zettel ML,Brown EB 3rd

    更新日期:2013-08-01 00:00:00

  • Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror.

    abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086005

    authors: Wang D,Fu L,Wang X,Gong Z,Samuelson S,Duan C,Jia H,Ma JS,Xie H

    更新日期:2013-08-01 00:00:00

  • Optical imaging of acute epileptic networks in mice.

    abstract::The potential of intrinsic optical imaging and resting-state analysis under anesthetized conditions as a tool to study brain networks associated with epileptic seizures is investigated. Using an acute model of epileptiform activity, the 4-aminopyridine model in live mice, we observe the changes in resting-state networ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.076021

    authors: Guevara E,Pouliot P,Nguyen DK,Lesage F

    更新日期:2013-07-01 00:00:00

  • Early detection of high-grade squamous intraepithelial lesions in the cervix with quantitative spectroscopic imaging.

    abstract::Quantitative spectroscopy has recently been extended from a contact-probe to wide-area spectroscopic imaging to enable mapping of optical properties across a wide area of tissue. We train quantitative spectroscopic imaging (QSI) to identify cervical high-grade squamous intraepithelial lesions (HSILs) in 34 subjects un...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.076013

    authors: Lau C,Mirkovic J,Yu CC,O'Donoghue GP,Galindo L,Dasari R,de las Morenas A,Feld M,Stier E

    更新日期:2013-07-01 00:00:00

  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Dual/differential coherent anti-Stokes Raman scattering module for multiphoton microscopes with a femtosecond Ti:sapphire oscillator.

    abstract::In the last decade, coherent anti-Stokes Raman scattering (CARS) microscopy has emerged as a powerful multiphoton imaging technique offering label-free chemical sensitivity and high three-dimensional resolution. However, its widespread application in the life sciences has been hampered by the use of costly pulsed lase...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.066004

    authors: Li B,Borri P,Langbein W

    更新日期:2013-06-01 00:00:00

  • Changes in the redox state and endogenous fluorescence of in vivo human skin due to intrinsic and photo-aging, measured by multiphoton tomography with fluorescence lifetime imaging.

    abstract::Ultraviolet radiation from solar exposure is a key extrinsic factor responsible for premature skin aging (i.e., photo-aging). Recent advances using in vivo multiphoton tomography (MPT) demonstrate the efficacy of this approach to assess intrinsic and extrinsic skin aging as an alternative to existing invasive techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.061217

    authors: Sanchez WY,Obispo C,Ryan E,Grice JE,Roberts MS

    更新日期:2013-06-01 00:00:00

  • Phase-function corrected diffusion model for diffuse reflectance of a pencil beam obliquely incident on a semi-infinite turbid medium.

    abstract::Oblique incidence reflectometry (OIR) is an established technique for the estimation of tissue optical properties. However, a sensing footprint of a few transport mean-free paths is often needed when diffusion-regime-based algorithms are used. Smaller-footprint probes require improved light-propagation models and inve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.067005

    authors: Zemp RJ

    更新日期:2013-06-01 00:00:00

  • Optical imaging for brain tissue characterization using relative fluorescence lifetime imaging.

    abstract::An autofluorescence lifetime wide-field imaging system that can generate contrast in underlying tissue structures of normal and malignant brain tissue samples with video rate acquisition and processing time is presented. Images of the investigated tissues were acquired with high resolution (∼35 μm) using an algorithm ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.060504

    authors: Papour A,Taylor Z,Sherman A,Sanchez D,Lucey G,Liau L,Stafsudd O,Yong W,Grundfest W

    更新日期:2013-06-01 00:00:00

  • Infrared laser thermal fusion of blood vessels: preliminary ex vivo tissue studies.

    abstract::Suture ligation of blood vessels during surgery can be time-consuming and skill-intensive. Energy-based, electrosurgical, and ultrasonic devices have recently replaced the use of sutures and mechanical clips (which leave foreign objects in the body) for many surgical procedures, providing rapid hemostasis during surge...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.058001

    authors: Cilip CM,Rosenbury SB,Giglio N,Hutchens TC,Schweinsberger GR,Kerr D,Latimer C,Nau WH,Fried NM

    更新日期:2013-05-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Monitoring remineralization of enamel subsurface lesions by optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is a potential clinical tool for enamel lesion monitoring. Swept-source OCT findings were compared with cross-sectional nanohardness findings of enamel. Subsurface bovine enamel lesions in three groups were subjected to (1) deionized water (control), (2) phosphoryl oligosaccharide of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.046006

    authors: Mandurah MM,Sadr A,Shimada Y,Kitasako Y,Nakashima S,Bakhsh TA,Tagami J,Sumi Y

    更新日期:2013-04-01 00:00:00

  • Monitoring hemodynamic and morphologic responses to closed head injury in a mouse model using orthogonal diffuse near-infrared light reflectance spectroscopy.

    abstract::The authors' aim is to assess and quantitatively measure brain hemodynamic and morphological variations during closed-head injury (CHI) in mice using orthogonal diffuse near-infrared reflectance spectroscopy (o-DRS). CHI is a type of injury to the head that does not penetrate the skull. Usually, it is caused by mechan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.045003

    authors: Abookasis D,Shochat A,Mathews MS

    更新日期:2013-04-01 00:00:00

  • Adaptive wide-field optical tomography.

    abstract::We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036006

    authors: Venugopal V,Intes X

    更新日期:2013-03-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Modeling of the temporal effects of heating during infrared neural stimulation.

    abstract::A model of infrared neural stimulation (INS) has been developed to allow the temporal characteristics of different stimulation parameters and geometries to be better understood. The model uses a finite element approach to solve the heat equation and allow detailed analysis of heat during INS with both microsecond and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035004

    authors: Thompson AC,Wade SA,Cadusch PJ,Brown WG,Stoddart PR

    更新日期:2013-03-01 00:00:00

  • Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.

    abstract::Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tiss...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.037005

    authors: Phillips JP,Cibert-Goton V,Langford RM,Shortland PJ

    更新日期:2013-03-01 00:00:00

  • Study of molecule variations in renal tumor based on confocal micro-Raman spectroscopy.

    abstract::Confocal micro-Raman spectroscopy--a valuable analytical tool in biological and medical field of research-allows probing molecular vibrations of samples without external labels or extensive preparation. We employ confocal micro-Raman spectroscopy to characterize renal tumors and normal tissue. Results show that Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.031103

    authors: Zhuang Z,Li N,Guo Z,Zhu M,Xiong K,Chen S

    更新日期:2013-03-01 00:00:00

  • Staining-free malaria diagnostics by multispectral and multimodality light-emitting-diode microscopy.

    abstract::We report an accurate optical differentiation technique between healthy and malaria-infected erythrocytes by quasi-simultaneous measurements of transmittance, reflectance, and scattering properties of unstained blood smears using a multispectral and multimode light-emitting diode microscope. We propose a technique for...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036002

    authors: Merdasa A,Brydegaard M,Svanberg S,Zoueu JT

    更新日期:2013-03-01 00:00:00

  • Evidence of a heterogeneous tissue oxygenation: renal ischemia/reperfusion injury in a large animal model.

    abstract::Renal ischemia that occurs intraoperatively during procedures requiring clamping of the renal artery (such as renal procurement for transplantation and partial nephrectomy for renal cancer) is known to have a significant impact on the viability of that kidney. To better understand the dynamics of intraoperative renal ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035001

    authors: Crane NJ,Huffman SW,Alemozaffar M,Gage FA,Levin IW,Elster EA

    更新日期:2013-03-01 00:00:00

  • Acoustic attenuation compensation in photoacoustic tomography using time-variant filtering.

    abstract::Most reconstruction algorithms used in photoacoustic tomography do not account for the effects of acoustic attenuation on the recorded signals. For experimental measurements made in biological tissue, the frequency dependent acoustic attenuation causes high frequency components of the propagating photoacoustic waves t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036008

    authors: Treeby BE

    更新日期:2013-03-01 00:00:00

  • Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

    abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.027003

    authors: Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

    更新日期:2013-02-01 00:00:00

  • Vessel orientation-dependent sensitivity of optoacoustic imaging using a linear array transducer.

    abstract::For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue ju...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.026011

    authors: Preisser S,Bush NL,Gertsch-Grover AG,Peeters S,Bailey AE,Bamber JC,Frenz M,Jaeger M

    更新日期:2013-02-01 00:00:00

  • Light propagation in a turbid medium with insonified microbubbles.

    abstract::Surfactant stabilized microbubbles are widely used clinical contrast agents for ultrasound imaging. In this work, the light propagation through a turbid medium in the presence of microbubbles has been investigated. Through a series of experiments, it has been found that the optical attenuation is increased when the mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.015002

    authors: Leung TS,Honeysett JE,Stride E,Deng J

    更新日期:2013-01-01 00:00:00

  • Analyzing reflectance spectra of human skin in legal medicine.

    abstract::Our current research in the framework of an interdisciplinary project focuses on modelling the dynamics of the hemoglobin reoxygenation process in post-mortem human skin by reflectance spectrometry. The observations of reoxygenation of hemoglobin in livores after postmortem exposure to a cold environment relate the re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.017004

    authors: Belenki L,Sterzik V,Schulz K,Bohnert M

    更新日期:2013-01-01 00:00:00

  • Understanding three-dimensional spatial relationship between the mouse second polar body and first cleavage plane with full-field optical coherence tomography.

    abstract::The morphogenetic relationship between early patterning and polarity formation is of fundamental interest and remains a controversial issue in preimplantation embryonic development. We use a label-free three-dimensional (3-D) imaging technique of full-field optical coherence tomography (FF-OCT) successfully for the fi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.010503

    authors: Zheng JG,Huo T,Chen T,Wang C,Zhang N,Tian N,Zhao F,Lu D,Chen D,Ma W,Sun JL,Xue P

    更新日期:2013-01-01 00:00:00

  • Specific absorption spectra of hemoglobin at different PO2 levels: potential noninvasive method to detect PO2 in tissues.

    abstract::Hemoglobin (Hb), as one of main components of blood, has a unique quaternary structure. Its release of oxygen is controlled by oxygen partial pressure (PO2). We investigate the specific spectroscopic changes in Hb under different PO2 levels to optimize clinical methods of measuring tissue PO2. The transmissivity of Hb...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.125002

    authors: Liu P,Zhu Z,Zeng C,Nie G

    更新日期:2012-12-01 00:00:00

  • Three-dimensional surface reconstruction within noncontact diffuse optical tomography using structured light.

    abstract::A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.126009

    authors: Baum K,Hartmann R,Bischoff T,Oelerich JO,Finkensieper S,Heverhagen JT

    更新日期:2012-12-01 00:00:00

  • Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation.

    abstract::In order to understand the relationship between accommodation and vision quality, a custom-built ultra-long scan depth spectral domain optical coherence tomography (UL-SDOCT) and a Shack-Hartmann wavefront sensor (HSWFS) were combined. The resolution and scan depth of UL-SDOCT are 6 μm and 15.6 mm, respectively, which...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.12.120501

    authors: Shi G,Wang Y,Yuan Y,Wei L,Lv F,Zhang Y

    更新日期:2012-12-01 00:00:00

  • Modulated electron-multiplied fluorescence lifetime imaging microscope: all-solid-state camera for fluorescence lifetime imaging.

    abstract::We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.jbo.17.12.126020

    authors: Zhao Q,Schelen B,Schouten R,van den Oever R,Leenen R,van Kuijk H,Peters I,Polderdijk F,Bosiers J,Raspe M,Jalink K,Geert Sander de Jong J,van Geest B,Stoop K,Young IT

    更新日期:2012-12-01 00:00:00

  • Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

    abstract::An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.11.110501

    authors: Fan C,Yao G

    更新日期:2012-11-01 00:00:00

  • High-speed upper-airway imaging using full-range optical coherence tomography.

    abstract::Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizi...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.jbo.17.11.110507

    authors: Jing J,Zhang J,Loy AC,Wong BJ,Chen Z

    更新日期:2012-11-01 00:00:00

  • Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy.

    abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116005

    authors: Rasta SH,Manivannan A,Sharp PF

    更新日期:2012-11-01 00:00:00

  • Ex vivo optical metabolic measurements from cultured tissue reflect in vivo tissue status.

    abstract::Optical measurements of metabolism are ideally acquired in vivo; however, intravital measurements are often impractical. Accurate ex vivo assessments would greatly broaden the applicability of optical measurements of metabolism. We investigate the use of live tissue culture experiments to serve as a surrogate for in v...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116015

    authors: Walsh AJ,Poole KM,Duvall CL,Skala MC

    更新日期:2012-11-01 00:00:00

  • Study on application of optical clearing technique in skin diseases.

    abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.115003

    authors: Shan H,Liang Y,Wang J,Li Y

    更新日期:2012-11-01 00:00:00

  • Analysis of the efficiency of hair removal by different optical methods: comparison of Trichoscan, reflectance confocal microscopy, and optical coherence tomography.

    abstract::Noninvasive diagnostic tools, such as Trichoscan®, reflectance confocal microscopy (RCM), and optical coherence tomography (OCT), are efficient methods of hair shaft and growth evaluation. The aim of this study was to carry out a comparative assessment of these three medical procedures by measuring the hair shaft and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,随机对照试验

    doi:10.1117/1.JBO.17.10.101504

    authors: Kuck M,Schanzer S,Ulrich M,Garcia Bartels N,Meinke MC,Fluhr J,Krah M,Blume-Peytavi U,Stockfleth E,Lademann J

    更新日期:2012-10-01 00:00:00

  • Noninvasive measurements of carotenoids in bovine udder by reflection spectroscopy.

    abstract::For a long time, the antioxidative status in cattle has been discussed as an indicator for stress conditions resulting from disease or exertion. Until now, invasive approaches have been necessary to obtain blood samples or biopsy materials and gain insights into the antioxidative status of cattle. Due to these efforts...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.101514

    authors: Klein J,Darvin ME,Müller KE,Lademann J

    更新日期:2012-10-01 00:00:00

  • Three-beam spectral-domain optical coherence tomography for retinal imaging.

    abstract::A three-beam spectral domain optical coherence tomography system (OCT) whose center wavelength is 840 nm was developed. The three beams focus on fundus 3.1 mm apart from each other and are detected by a single line sensor. The distance between the beams is fixed and the beams scan a total area of 10×10  mm² while keep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106001

    authors: Suehira N,Ooto S,Hangai M,Matsumoto K,Tomatsu N,Yuasa T,Yamada K,Yoshimura N

    更新日期:2012-10-01 00:00:00

  • Evaluation and quantification of spectral information in tissue by confocal microscopy.

    abstract::A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106011

    authors: Maeder U,Marquardt K,Beer S,Bergmann T,Schmidts T,Heverhagen JT,Zink K,Runkel F,Fiebich M

    更新日期:2012-10-01 00:00:00

602 条记录 7/16 页 « 12...45678910...1516 »